Quatech Parallel PCMCIA Card with security dongles

Here is a list of security dongles that have been tested with the Quatech Parallel PCMCIA cards. It is rare for these suggestions to not work, so try them, and if they dont work, contact either the manufacturer of the dongle, Quatech, or our support team.

Rainbow Security Dongle

Follow the directions below to configure the Sentinel System Driver to work with a SPP-100 parallel PCMCIA card under Windows 2000 and XP. The Sentinel System Driver 5.41 can be configured to work with the SPP-100. I usually suggest for the customer to download the current drivers for the dongle especially customers using XP. These can be located at SafeNet-inc.com.

    Hardware Configuration

1. From the Control Panel, double-click the System icon to open the System Properties page.
2. Click the Hardware tab and then the Device Manager button to open the Device Manager.
3. Click the + sign next to Ports (COM & LPT) to expand the tree.
4. Double-click on SPP-100 to open the property page.
5. Click on the Resources tab to see the resources used by the adapter. The value listed next to the I/O range will be the bus address the Sentinel software will be looking for, so be certain to write this value down.
6. Sentinel Software Configuration

    Install the Sentinel System Driver

1. Start the driver configuration utility, SetupSysDriver.exe. It is usually located at C:\Program Files\Rainbow Technologies\Sentinel System Driver.
2. Click the “Configure Driver” button.
3. Then click the “Add” button.
4. Enter the I/O address of the SPP-100 parallel port card into the “Bus Address” field. Please leave all other options at the default value.
5. Click the “OK” button.
6. The next screen shows that a User Created port has been added.
7. Click the Add button to close the dialog and then open the File menu and choose Exit to close the Sentinel System Driver Configuration Utility.
8. The Sentinel System Driver should now be configured to use the Quatech Parallel PCMCIA card.

Aladdin or Hasp dongles

This information was provided by the Aladdin/Hasp support team. This seems to work sometimes but there is contact information from the Aladdin/Hasp support. for additional help:

The Hasp/Aladdin dongle has a configuration utility that needs to be told what base address the parallel port is installed at.

1. Set the port to LPT1 with a manual I/O address range of 478 - 47F (automatic setting chooses FFF8 - FFFF).
2. Unzip and extract the hinstall.exe and the haspds_windows.dll files to the same folder.

Remove the previous version of the HASP Device Driver by doing the following:

4. Click on Start.
5. Scroll up to Run.
6. Click on Browse and look for the hinstall.exe file.
7. At the end of the path, type in -r -kp -alldrv It should look something like this depending on where you put the hinstall.exe file.

C:/hinstall.exe -r -kp -alldrv

8. Install the latest version of the HASP Device Driver by doing the following:
9. Click on Start.
10. Scroll up to Run.
11. Click on Browse and look for the hinstall.exe file.
12. At the end of the path, type in -i
13. It should look something like this depending on where you put the hinstall.exe file.

C:/hinstall.exe -i

You can contact the support team at Alladin/Hasp by calling 800-223-4277 or writing to support.us@ealaddin.com.

Metrowerks Code Warrior/OCDemon Wiggler

Metrowerks uses a Command Converter Server which is part of the CodeWarrior software. The CCS usually appears in the icon window next to the time once the OCDemon Wiggler is tried. Double click on the icon for the CCS. This will open a window that looks and acts like a command prompt. The following commands need to be entered.

delete all

config cc lpt:0xFFF0 (where 0xFFF0 is the address of the parallel port)

save cc

config save

These commands should point the CCS to the correct parallel port, save the configuration for later use, and allow use

DK2 Dongle

The latest DK2 driver installation (v6.08.0.154) can be found here, it includes support for Windows XP :
http://www.deskey.co.uk/deskey_downloads.php. I would recommend using LPT address of $378,$278 or $3bc.

Depending on how the PCMCIA device implements its driver the DESkey drivers may not be able to find the LPT port, you can hard code the address the DK2 to be searched by adding it as a DWORD registry value named ‘LPTPort’ in ‘HKLM\System\CurrentControlSet\Services\dk2drv\Parameters’.

Keylok and Husqvarna Viking Security Dongles

Keylok and the Husqvarna Viking security dongles are not compatible with the Quatech Parallel PCMCIA. Both manufacturer’s say that their dongles will not work with a USB or PCMICA parallel port.

4 Responses to “Quatech Parallel PCMCIA Card with security dongles”

  1. joseph Says:

    canopus procoder,aladin HASP divice manager problem

  2. mazhar Says:

    Hi,
    I have quatech spp-100 card ,I need to the parallel port to work in ECP mode not EPP mode as my application required DMA 3 ,address 3BC
    Would you please support me to solve this problem
    Regards
    Mazhar

  3. mazhar Says:

    Hi,
    I have PCMCIA card Quatech SPP-100
    WORK IN EPP MODE BUT MY APPLICATION REQUIRED TO WORK IN ECP MODE ADDRESS 3BC
    WOULD YOU PLEASE SUPPORT ME TO CONVERT EPP MODE TO ECP MODE
    THANKS

  4. mazhar Says:

    Hi,
    I have laptop HP NX6110 with 2 USB ports , no parallel port , or serial port

    I have bought Quatech SPP-100 PCMCIA card

    The device manager screen indicate 1 parallel port (LPT1 ) found But I was received from your site that this card SPP-100 will generate true parallel port ( ECP mode ) My application is to download software using parallel port to digital Xerox machine when I try to download the software an error message appeared ” error opening parallel device ”

    Finally , I returned the card back to supplier

    I need to switch the card operation to ECP mode

    Would you please support meWhat kind of card work in ECP support , bidirectional data , address 3BC, DMA 3 ?

    Please advise

    Regards

Leave a Reply

c1608e58b7a40647381b4667630bf061

Notice: Undefined index: p in /usr/home/sewell/www/htdocs/wp-content/plugins/SK2/sk2_plugins/func_sk2_blacklist_plugin.php on line 118
82d58bfc8dc7a2fa985939b01d5b694f 69175bee376c12eba6ddbd1f632a7f10

Notice: Undefined variable: sk2_rand_str in /usr/home/sewell/www/htdocs/wp-content/plugins/SK2/sk2_functions.php on line 140